Emulator Target Voltage
Problem
A: target voltage with current-measurement is unstable (oscillation for low voltage / low load)
B: voltage buffer feedback is excluding the switch afterward
Setup
BB powered by bench-supply
Target voltage drained by keithley source meter (current mode)
target voltage is monitored by scope with probe in AC-Mode to analyze Noise
NOTE: part of the oscillation is probably also partly caused by the measurement setup ⇾ heisenbug
Measurements for unstable Voltage
VTarget = 0.5 V shows 10mVpp oscillation ~ 260 kHz
VTarget = 1.0 V is stable
other documentation is lost
problem is fixed
Measurements for voltage drop
source current ⇾ TargetA Voltage
0 uA; 2.9983 V
1 mA; 2.9987 V
5 mA; 3.0001 V
10 mA; 3.0024 V
20 mA; 3.0065 V
30 mA; 3.0106 V
40 mA; 3.0148 V
drain current ⇾ TargetA Voltage
0 mA; 2.9983 V
1 mA; 2.9979 V
10 mA; 2.9942 V
20 mA; 2.9901 V
30 mA; 2.9860 V
40 mA; 2.9818 V
50 mA; 2.9732 V
Analysis of voltage drop
side node: shepherd is able to drain power
drain-experiment shows voltage drop of 25.1 mV for 50 mA ⇾ 502 mOhm Internal Resistance after OpAmp
switch-datasheet claims 500 mOhm Rds_on ⇾ very close to measurement including traces
influence of switch ⇾ 50mA @ 3V equals 60 Ohm ⇾ 500 mOhm are 0.83 % of that
Conclusion
A: oscillation can be fixed by bigger shunt-resistance
B: voltage drop can be fixed by including switch into feedback loop ⇾ needs additional switch